FEATURES: * MDD CE certified medical device. * Individual or grouped control of the gain and filtering characteristics of amplifier channels. * Impedance checking feature allows tri-colour LEDs to indicate problems with any electrodes. * Notch filter (factory set to 50Hz or 60Hz). Large range of low-cut and high-cut band-pass filter settings. * Overall gain of x100 to x3,000,000 with outputs at the front (BNC) or rear (D-type) of the main unit.
- Computer controlled 8-channel patient-isolated biological amplifier and analogue filter system, CE marked according to the Medical Device Directive. The system comprises a main amplifier unit, a remote active head-box and dedicated Windows (2000, NT, XP) compatible control software (operators manual and software updates are available here).
-
-
Multiple D360 systems can be connected to a single computer (via a single serial port) to allow multiples of 8 channels to be controlled through a single software interface.
-
-
The D360 is ideally suited to research or diagnostic use, as an electroencephalography amplifier (EEG), electromyography amplifier (EMG) or evoked potential amplifier (EP).
-
-
CE Certified for Human Use
-
Certified to the EU Medical Devices Directive, the D360 is an 8-channel isolated amplifier specifically designed for human electro-encephalography (EEG), electro-myography (EMG) or evoked potential (EP) studies. The system comprises a main amplifier unit with a remote active headbox and dedicated Microsoft WindowsTM compatible control software.
-
-
Daisy Chain Multiple D360 for Greater Channel Number
-
Multiple D360 amplifier systems can be connected to a single PC allowing multiples of 8 channels to be controlled by one PC system. Electrode connection is via touch-proof 1.5mm (DIN 42 802) sockets on the headbox and signal output to your chosen acquisition device is possible either through the eight BNC connectors on the front panel or a pair of “D” connectors at the rear of the main unit.
-
-
Software Control Program Runs in the Background During Acquisition
-
Because the WindowsTM compatible D360 Control Software can run in parallel with your data acquisition program, adjustments to the amplifier settings or tasks such as impedance checking and deblocking can be made while still monitoring data collection.
-
-
External TTL Controlled De-block (Optional Feature)
-
D360 Amplifiers can include an external de-block BNC input, which allows the operator to “gate” the de-block function of the amplifier with a TTL-high command. This special modification is particularly useful for D360 operators who need the amplifier to detect responses with short latency responses following a magnetic stimulus.
-
Detaylı bilgi için 0553.904-31-95 numaralı telefonumuzdan bize ulaşabilir veya bilgim@dev-med.com adresimize mail gönderebilirsiniz.
-
Üreticinin web sitesine ulaşmak için: http://www.digitimer.com